Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 292
Filter
1.
Eur J Heart Fail ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726573

ABSTRACT

AIM: This analysis aimed to compare the clinical outcomes associated with heart failure (HF) readmissions and to identify associations with HF hospitalizations (HFH) in patients treated with the MitraClip™ NTR/XTR System in the EXPAND study. METHODS AND RESULTS: The global, real-world EXPAND study enrolled 1041 patients with primary or secondary mitral regurgitation (MR) treated with the MitraClip NTR/XTR System. Echocardiograms were analysed by an independent echocardiographic core laboratory. The study population was stratified into HFH and No-HFH groups based on the occurrence of HFH 1 year post-index procedure. Clinical outcomes including MR severity, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ) score, and all-cause mortality were compared (HFH: n = 181; No-HFH: n = 860). Both groups achieved consistent 1-year MR reduction to ≤1+ (HFH vs. No-HFH: 87.3% vs. 89.5%, p = 0.6) and significant 1-year improvement in KCCQ scores (+16.5 vs. +22.3, p = 0.09) and NYHA functional class. However, more patients in the No-HFH group had 1-year NYHA class ≤II (HFH vs. No-HFH: 67.9% vs. 81.9%, p < 0.01). All-cause mortality at 1 year was 36.8% in the HFH group versus 10.4% in the No-HFH group (p < 0.001). The HFH rate decreased by 63% at 1 year post-M-TEER versus 1 year pre-treatment (relative risk 0.4, p < 0.001). Independent HFH associations were MR ≥2+ at discharge, HFH 1 year prior to treatment, baseline NYHA class ≥III, baseline tricuspid regurgitation ≥2+, and baseline left ventricular ejection fraction ≤40%. CONCLUSIONS: This study reports the impact of HFH on clinical outcomes post-treatment in the EXPAND study. Results demonstrate that the occurrence of HFH was associated with worse 1-year survival, and treatment with the MitraClip system substantially reduced HFH and improved patient symptoms and quality of life.

2.
J Clin Med ; 13(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38731005

ABSTRACT

Background: Complex arrhythmias often arise from the left side of the heart, necessitating established electrophysiological (EP) procedures like 3D-mapping-assisted radiofrequency (RF) ablations or pulmonary vein isolation (PVI). These procedures typically require transseptal access, emphasizing the critical role of achieving an optimal catheter position through a precise transseptal puncture (TSP). Commonly employed imaging methods for TSP guidance include fluoroscopy and interventional echocardiography. Despite their routine use, there is limited evidence on which imaging modality offers superior catheter positioning for EP procedures, and safety concerns regarding transseptal punctures with imaging remain underexplored. This study aims to systematically evaluate the feasibility, safety, and accuracy of echo-guided TSP compared to fluoroscopy-guided TSP. Methods: In this prospective study, 150 consecutive patients undergoing left atrial EP procedures were enrolled between October 2023 and February 2024 at the Ulm University Heart Center. Following optimal fluoroscopy-guided transseptal needle positioning at the interatrial septum, the catheter placement was further verified using transesophageal echocardiography (TEE). Adjustments were made in cases of suboptimal needle positioning observed in TEE. The fluoroscopically achieved septal positions were categorized based on TEE images as optimal, suboptimal, poor, or dangerous. Results: Among the 150 patients included (58.0% male), fluoroscopy achieved optimal, suboptimal, and poor/dangerous positions in 32.7%, 43.3%, and 24.0%, respectively. After TEE-guided adjustments, optimal and suboptimal positions were achieved in 59.3% and 40.7% of patients, respectively. No instances of poor or dangerous transseptal needle positions were observed under TEE guidance. Conclusions: TEE-guided TSP emerges as a feasible, more accurate, and safer imaging method for transseptal punctures in EP procedures.

3.
Article in German | MEDLINE | ID: mdl-38625382

ABSTRACT

In Germany, physicians qualify for emergency medicine by combining a specialty medical training-e.g. internal medicine-with advanced training in emergency medicine according to the statutes of the State Chambers of Physicians largely based upon the Guideline Regulations on Specialty Training of the German Medical Association. Internal medicine and their associated subspecialities represent an important column of emergency medicine. For the internal medicine aspects of emergency medicine, this curriculum presents an overview of knowledge, skills (competence levels I-III) as well as behaviours and attitudes allowing for the best treatment of patients. These include general aspects (structure and process quality, primary diagnostics and therapy as well as indication for subsequent treatment; resuscitation room management; diagnostics and monitoring; general therapeutic measures; hygiene measures; and pharmacotherapy) and also specific aspects concerning angiology, endocrinology, diabetology and metabolism, gastroenterology, geriatric medicine, hematology and oncology, infectiology, cardiology, nephrology, palliative care, pneumology, rheumatology and toxicology. Publications focussing on contents of advanced training are quoted in order to support this concept. The curriculum has primarily been written for internists for their advanced emergency training, but it may generally show practising emergency physicians the broad spectrum of internal medicine diseases or comorbidities presented by patients attending the emergency department.

4.
J Clin Med ; 13(8)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38673445

ABSTRACT

(1) Objective: We aimed to assess whether the candidate profile, the long-term outcomes and the predictors for long-term mortality after transcatheter edge-to-edge mitral valve repair (M-TEER) have changed over the last decade; (2) Methods: Long-term follow-up data (median time of 1202 days) including mortality, MACCE and functional status were available for 677 consecutive patients enrolled in the prospective MiTra Ulm registry from January 2010 to April 2019. The initial 340 patients treated in our institution before January 2016 were compared with the following 337 patients; (3) Results: Patients treated after 2016 showed significantly less ventricular dilatation (left ventricular end-systolic diameter of 43 ± 13 mm vs. 49 ± 16 mm, p < 0.007), lower systolic pulmonary pressures (50 ± 15 mmHg vs. 57 ± 21 mmHg, p = 0.01) and a lower prevalence of severe tricuspid regurgitation (27.2% vs. 47.3%, p < 0.001) at baseline than patients treated before 2016. Compared to the cohort treated before 2016, patients treated afterwards showed a significantly lower all-cause 3-year mortality (29.4% vs. 43.8%, p < 0.001) and lower MACCE (38.6% vs. 54.1%, p < 0.001), without differences for MR etiology. While severe tricuspid regurgitation and NYHA class IV remained independently associated with an increased long-term mortality over the last decade, severe left ventricular dilatation (hazard ratio, HR 2.12, p = 0.047) and severe pulmonary hypertension (HR 2.18, p = 0.047) were predictors of long-term mortality only in patients treated before 2016. (4) Conclusions: The M-TEER candidates are currently treated earlier in the course of disease and benefit significantly in terms of a better long-term survival than patients treated at the beginning of the M-TEER era.

5.
J Clin Med ; 13(8)2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38673535

ABSTRACT

Background: Pulmonary vein isolation (PVI) is a common therapeutic approach for symptomatic atrial fibrillation (AF). Among various techniques, cryo-balloon (CB) PVI is widely adopted, but, to date, established CB systems have had fixed balloon sizes. A novel size-adjustable CB, allowing balloon size adjustments during ablation, lacks sufficient data on optimal utilization in patient care. This study aims to systematically investigate this feature with a tailored ablation protocol. Methods: Our single-center prospective study included patients with paroxysmal or persistent atrial fibrillation undergoing first-time PVI with the size-adjustable CB from July 2023 to February 2024. Ablation was performed using the balloon size that provided better occlusion. The ablation protocol involved an initial occlusion test with the small balloon size (28 mm). If optimal occlusion (occlusion level 4) could not be achieved, an attempt with the larger balloon (31 mm) was initiated. Ablation was conducted using the balloon configuration that provided better occlusion of the pulmonary vein ostium. Results: Our prospective study includes 50 patients (median age [interquartile range, IQR]: 72 [65; 79] years, 24 [48.0%] females, and 35 [70.0%] patients with paroxysmal AF). The median procedure duration (IQR) was 77 (65; 96) minutes, and the median fluoroscopy time (IQR) was 17.7 (12.5; 22.0) min. PVI was successfully accomplished in each treated pulmonary vein (PV), with 87.4% of PVs isolated during the first freeze. The large balloon configuration was used to isolate 16.8% of PVs. Conclusions: The utilization of the size-adjustable CB, combined with the presented tailored ablation workflow, appears to facilitate effective and efficient pulmonary vein isolation. The use of a larger balloon configuration appears beneficial in isolating a significant proportion of the PVs.

6.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599692

ABSTRACT

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Follow-Up Studies , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
7.
Clin Res Cardiol ; 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38446147

ABSTRACT

BACKGROUND: Patients, whose non-emergency cardiac procedure was postponed during the COVID-19 pandemic, have shown signs of disease progression in the short term. Data on the long-term effects are currently lacking. AIM: To assess outcomes through 3 years following deferral. METHODS: This retrospective, single-center analysis includes consecutive patients whose non-emergency cardiovascular intervention was postponed during the first COVID-19-related lockdown (March 19 to April 30, 2020). Outcomes over 36 months post-procedure were analyzed and compared to a seasonal control group undergoing non-emergency intervention in 2019 as scheduled (n = 214). The primary endpoint was a composite of emergency cardiovascular hospitalization and death. Additionally, NT-proBNP levels were analyzed. RESULTS: The combined endpoint occurred in 60 of 178 patients (33.7%) whose non-emergency transcatheter heart valve intervention, rhythmological procedure, or left heart catheterization was postponed. Primary endpoint events did not occur more frequently in the study group during the 36-month follow-up (p = 0.402), but within the first 24 months post-procedure (HR 1.77, 95% CI 1.20-2.60, p = 0.003). Deferred patients affected by an event in the postprocedural 24 months had significantly higher NT-proBNP levels at the time of intervention (p < 0.001) (AUC 0.768, p = 0.003, optimum cut-off 808.5 pg/ml, sensitivity 84.2%, specificity 65.8%) and thereafter (p < 0.001). CONCLUSION: Deferral of non-emergency cardiovascular interventions is associated with poor outcomes up to 24 months post-procedure. Adverse effects affect patients who develop signs of acute heart failure, as indicated by NT-proBNP, prior to treatment. These findings could help improve resource allocation in times of limited capacity.

9.
J Clin Med ; 13(4)2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38398276

ABSTRACT

Background/Objectives: Single-shot devices are important tools for efficient pulmonary vein isolation (PVI) in atrial fibrillation (AF). In addition to the standard cryo-balloon (CB) catheter, a novel multi-electrode radiofrequency balloon-catheter (RFB, Heliostar, Biosense Webster, Irvine, CA, USA) with 3D-mapping-integration is available. Currently, there is no evidence allowing for a direct comparison between RFB-PVI and CB-PVI in a matched population. The study aimed to assess the procedural data, safety profiles, and outcomes of RFB-PVI versus CB-PVI. Methods: In this prospective registry study, symptomatic AF patients undergoing first-time PVI from January 2019 to April 2023, using RFB or CB, were included, with patients matched in a 1:2 ratio to reduce potential confounders. Results: The results from 171 consecutive RFB patients and 342 matched CB patients showed comparable recurrence-free survival after 12 months (81.3% RFB vs. 76.8% CB, p = 0.359). The RFB group had a longer procedure duration (88 vs. 73 min, p < 0.001) and longer fluoroscopy time (18.9 vs. 14.5 min, p < 0.001). Conclusions: In conclusion, the novel RFB system enables efficient and safe PVI, which is broadly comparable to the established CB system. However, the 3D-mapping integration in RFB did not reduce fluoroscopy time compared to CB.

10.
Clin Res Cardiol ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38353680

ABSTRACT

BACKGROUND: Transcatheter edge-to-edge mitral valve repair (M-TEER) is often performed in general anesthesia, and postprocedural monitoring is usually warranted on an intensive or intermediate care unit (ICU/IMC). We evaluated the implications of a dedicated valve unit (VU) instead of an ICU/IMC for monitoring after M-TEER. METHODS AND RESULTS: In total, 624 patients were retrospectively analyzed. A total of 312 patients were primarily transferred to either ICU or IMC following M-TEER, and 312 patients were scheduled for the VU in the absence of indications for ICU/IMC treatment. Hospital stay was significantly shorter in VU patients (median 6.0 days (interquartile range (IQR) 5.0 - 8.0) vs. 7.0 days (IQR 6.0 - 10.0), p < 0.001) and their risk for infections (2.9 vs. 7.7%, p = 0.008) and delirium (0.6 vs. 2.6%, p = 0.056) was substantially lower compared to ICU/IMC patients. In-hospital mortality was similar in both groups (0.6% vs. 1.3%, p = 0.41). Fifty patients (16.0%) in the VU group had to cross over to unplanned ICU/IMC admission. The most frequent indication was prolonged need for catecholamines (52.0%). Patients with ICU/IMC crossover had more advanced stages of heart failure (LV-EF < 30% in 36.0 vs. 16.0%, p = 0.001; severe concomitant tricuspid regurgitation in 48.0 vs. 27.8%, p = 0.005) and an LV-EF < 30% was independently associated with unplanned ICU/IMC admission. CONCLUSIONS: Following M-TEER postprocedural monitoring on a VU instead of an ICU/IMC is safe, reduces complications, and spares ICU capacities. Patients with advanced heart failure have a higher risk for unplanned ICU/IMC treatment after M-TEER.

11.
Clin Res Cardiol ; 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38270636

ABSTRACT

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is an established treatment for functional mitral regurgitation (FMR) associated with a risk of creating iatrogenic stenosis. OBJECTIVES: To investigate the impact of the P10 and its larger spacer compared to the narrower Ace and its smaller spacer on reduction of mitral valve orifice area (MVOA) during M-TEER. METHODS: Consecutive patients undergoing M-TEER for treatment of severe FMR were screened retrospectively. Patients with a single PASCAL device implantation within the central segments of the MV leaflets, non-complex anatomy, and baseline MVOA ≥ 3.5cm2 were selected. Intraprocedural transesophageal echocardiography was used to compare MVOA reduction with 3D multiplanar reconstruction and direct planimetry. Device selection did not follow a prespecified MVOA threshold. RESULTS: Seventy-two patients (81.0 years, IQR {74.3-85.0}) were included. In 32 patients, the P10 was implanted (44.4%). MR severity (p = 0.66), MR reduction (p = 0.73), and body surface area (p = 0.56) were comparable. Baseline MVOA tended to be smaller in P10 patients with the larger spacer (5.0 ± 1.1 vs. 5.4 ± 1.3cm2, p = 0.18), however, residual MVOA was larger in these patients (2.7 ± 0.7 vs. 2.3 ± 0.6cm2, p = 0.03). Accordingly, relative MVOA reduction was significantly less in P10 patients (- 45.9 ± 7.6 vs. - 56.3 ± 7.0%, p < 0.01). Indirect annuloplasty was more pronounced in Ace patients whereas mean transmitral gradients were similar. CONCLUSION: In FMR patients with non-complex anatomy, the larger spacer of the P10 maintains greater MVOA with similar MR reduction. Hence, the use of the PASCAL Ace device in patients with small MVOAs might correlate with a risk of both clinically relevant orifice reduction and even iatrogenic stenosis.

12.
Int J Cardiovasc Imaging ; 40(2): 225-235, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38001273

ABSTRACT

BACKGROUND: Breast cancer is a common and increasingly treatable disease. However, survivors have a significantly elevated risk of cardiac events afterwards. This study aimed to characterise cardiac changes during cardiotoxic cancer therapy using cardiovascular magnetic resonance (CMR) imaging. METHODS: This study involved 34 patients with histologically proven breast cancer and planned cardiotoxic therapy. All patients underwent CMR before starting therapy, and 6 and 12 months thereafter. The CMR protocol included volumetric and functional analyses, parametric mapping, and deformation analysis using feature tracking. As the control group, 10 healthy female volunteers were scanned using the same protocol. RESULTS: With therapy, there was a significant reduction of left ventricular and right ventricular ejection fractions (both p < 0.05) without reaching pathologic values. Left ventricular radial (p = 0.008), circumferential (p = 0.010), and longitudinal strain (p = 0.036) were also reduced at follow-up. In the parametric mapping, there was a significant increase in native T1 time (start: 1037 ± 41 ms vs. 6 months: 1068 ± 51 ms vs. 12 months: 1017 ± 57 ms, p < 0.001) and T2 time (start: 55 ± 4 ms vs. 6 months: 59 ± 3 ms vs. 12 months: 57 ± 3 ms, p = 0.001), with unchanged extracellular volume and relative late gadolinium enhancement. Twelve months after cancer diagnosis, the breast cancer patients exhibited significant impairments in left ventricular global radial (p = 0.001), circumferential (p = 0.001), and longitudinal strain (p = 0.002) and T2 time (p = 0.008) compared to the healthy controls. DISCUSSION: Breast cancer patients receiving cardiotoxic chemotherapy show persistent deterioration in left ventricular strain values. This is accompanied by inflammatory changes in non-invasive tissue characterisation. Larger studies with longer follow-up periods are needed to identify patients at risk and establish preventive and therapeutic approaches.


Subject(s)
Breast Neoplasms , Humans , Female , Breast Neoplasms/drug therapy , Ventricular Function, Left , Contrast Media , Magnetic Resonance Imaging, Cine/methods , Predictive Value of Tests , Gadolinium , Cardiotoxicity
13.
Front Cardiovasc Med ; 10: 1269833, 2023.
Article in English | MEDLINE | ID: mdl-38107259

ABSTRACT

Background: Conduction disturbances demanding permanent pacemaker implantation (PPI) remain a common complication after transcatheter aortic valve replacement (TAVR). Optimization of the implantation depth (ID) by introducing the cusp-overlap projection (COP) technique led to a reduced rate of PPI when self-expanding valves were used. Objectives: The aim of the present study was to determine if using the novel COP view is applicable for all types of TAVR prosthesis and results in a higher ID and reduced incidence of new conduction disturbances and PPI. Methods: In this prospective case-control study 586 consecutive patients undergoing TAVR with either balloon-expandable Edwards SAPIEN S3 (n = 280; 47.8%), or mechanically expandable Boston LOTUS Edge heart valve prostheses (n = 306; 52.2%) were included. ID as well as rates of periprocedural PPI and left bundle branch block (LBBB) were compared between the conventional three-cusp coplanar (TCC) projection and the COP view for implantation. Results: Of 586 patients, 282 (48.1%) underwent TAVR using COP, whereas in 304 patients (51.9%) the TCC view was applied. Using COP a significantly higher ID was achieved in Edwards SAPIEN S3 TAVR procedures (ID mean difference -1.0 mm, 95%-CI -1.9 to -0.1 mm; P = 0.029), whereas the final platform position did not differ significantly between both techniques when a Boston LOTUS Edge valve was used (ID mean difference -0.1 mm, 95%-CI -1.1 to +0.9 mm; P = 0.890). In Edwards SAPIEN S3 valves, higher ID was associated with a numerically lower post-procedural PPI incidence (4.9% vs. 7.3%; P = 0.464). Moreover, ID was significantly deeper in patients requiring PPI post TAVR compared to those without PPI [8.7 mm (6.8-10.6 mm) vs. 6.5 mm (6.1-7.0 mm); P = 0.005]. In Boston LOTUS Edge devices, COP view significantly decreased the incidence of LBBB post procedure (28.1% vs. 47.9%; P < 0.001), while PPI rates were similar in both groups (21.6% vs. 25.7%; P = 0.396). Conclusion: The present study demonstrates the safety, efficacy and reproducibility of the cusp-overlap view even in balloon-expandable and mechanically-expandable TAVR procedures. Application of COP leads to significantly less LBBB in repositionable Boston LOTUS Edge valves and a numerically lower PPI rate in Edwards SAPIEN S3 valves post TAVR compared to the standard TCC projection. The results should encourage to apply the COP view more widely in clinical practice.

14.
Sci Rep ; 13(1): 22679, 2023 12 19.
Article in English | MEDLINE | ID: mdl-38114601

ABSTRACT

Nexilin (NEXN) plays a crucial role in stabilizing the sarcomeric Z-disk of striated muscle fibers and, when mutated, leads to dilated cardiomyopathy in humans. Due to its early neonatal lethality in mice, the detailed impact of the constitutive homozygous NEXN knockout on heart and skeletal muscle morphology and function is insufficiently investigated. Here, we characterized a constitutive homozygous CRISPR/Cas9-mediated nexn knockout zebrafish model. We found that Nexn deficient embryos developed significantly reduced cardiac contractility and under stressed conditions also impaired skeletal muscle organization whereas skeletal muscle function seemed not to be affected. Remarkably, in contrast to nexn morphants, CRISPR/Cas9 nexn-/- knockout embryos showed a milder phenotype without the development of a pronounced pericardial edema or blood congestion. nexn-specific expression analysis as well as whole transcriptome profiling suggest some degree of compensatory mechanisms. Transcripts of numerous essential sarcomeric proteins were massively induced and may mediate a sarcomere stabilizing function in nexn-/- knockout embryos. Our findings demonstrate the successful generation and characterization of a constitutive homozygous nexn knockout line enabling the detailed investigation of the role of nexn on heart and skeletal muscle development and function as well as to assess putative compensatory mechanisms induced by the loss of Nexn.


Subject(s)
Microfilament Proteins , Zebrafish , Humans , Animals , Mice , Zebrafish/genetics , Zebrafish/metabolism , Microfilament Proteins/metabolism , CRISPR-Cas Systems , Muscle Contraction/genetics , Muscle, Skeletal/metabolism , Zebrafish Proteins/genetics , Zebrafish Proteins/metabolism
16.
JACC Cardiovasc Interv ; 16(23): 2854-2865, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37999708

ABSTRACT

BACKGROUND: A significant number of patients with severe mitral regurgitation (MR) are not suitable for either surgical or transcatheter edge-to-edge repair because of high surgical risk or inappropriate mitral valve anatomy. OBJECTIVES: The aim of this study was to evaluate the HighLife Trans-Septal Mitral Valve Replacement (TSMVR) system in patients with symptomatic MR and high surgical risk. METHODS: This prospective, multicenter, nonrandomized feasibility study evaluated the safety and performance of the HighLife TSMVR system in patients with moderate to severe or severe symptomatic MR during 1-year follow-up. Echocardiographic data were assessed at an independent core laboratory. RESULTS: A total of 30 patients (mean age 75.6 years, 27% women, median Society of Thoracic Surgeons score 5.5%) with severe MR (90% with secondary MR, median left ventricular ejection fraction 43%) were treated at 13 sites. In 27 of the 30 patients, the HighLife TSMVR system was implanted successfully (technical success rate 90%). Device success at 30 days was 83%. After 1 year, 5 patients (17%) had died. None of the patients who underwent implantation required mitral valve reintervention. All patients who underwent implantation had no or trace (78%) or mild (22%) MR, the mean gradient of the HighLife valve was 5.1 mm Hg, and there were no signs of left ventricular outflow tract obstruction (mean gradient 2.0 mm Hg). CONCLUSIONS: The 1-year results from the HighLife TSMVR feasibility study demonstrate a high technical success rate, excellent valve function, no left ventricular outflow tract obstruction, and no need for mitral valve reintervention. Additional patient outcomes and longer follow-up are needed to confirm these findings. (Expanded Study of the HighLife 28mm Trans-Septal Trans-Catheter Mitral Valve in Patients With Moderate-Severe or Severe Mitral Regurgitation and at High Surgical Risk; NCT04029363).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Aged , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Stroke Volume , Feasibility Studies , Prospective Studies , Ventricular Function, Left , Treatment Outcome , Cardiac Catheterization
17.
J Clin Med ; 12(19)2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37834835

ABSTRACT

BACKGROUND: Improvement in concomitant tricuspid regurgitation (TR) after mitral valve transcatheter edge-to-edge repair (M-TEER) for mitral regurgitation (MR) occurs frequently; however factors determining the post-procedural course of TR are not well understood. We investigated the parameters associated with TR improvement after M-TEER. METHODS AND RESULTS: A total of 300 patients were consecutively included in this retrospective analysis. MR and TR severity as well as heart chamber metrics were assessed before the procedure and at follow-up. Device success was achieved in 97.3% of patients. TR decreased in 30.2% of patients. Patients with improved TR were more often female, had more severe TR at baseline, and their right heart dimensions at baseline trended to be smaller. Female sex (odds ratio (OR) 2.997), baseline MR-Grade (OR 3.181) and baseline TR-Grade (OR 2.653) independently predicted TR reduction. More pronounced right heart reverse remodeling was observed in patients with improved TR. TR regression independently predicted lower mortality (hazard ratio (HR) 0.333, 95% confidence interval 0.112-0.996, p = 0.049). CONCLUSIONS: A reduction in concomitant TR severity after M-TEER occurred mainly in females and in patients with high-grade TR and MR at baseline. TR regression is associated with better survival after M-TEER.

18.
Sci Rep ; 13(1): 18215, 2023 10 25.
Article in English | MEDLINE | ID: mdl-37880316

ABSTRACT

Approximately one fifth of patients diagnosed with atrial fibrillation (AF) undergo a percutaneous coronary intervention (PCI). Current guidelines recommend different combinations and durations of triple or dual antithrombotic therapy for these patients but data on the implementation of these recommendations in clinical routine are scarce. ENCOURAGE-AF is a prospective, non-interventional, non-comparative, multicentre study. Approximately 720 patients will be consecutively enrolled from 70 participating sites across Germany. Patients with non-valvular AF treated with edoxaban, who have undergone successful PCI, have no planned elective cardiac intervention during the study period, have capability, availability, and willingness for follow-up by telephone interview during the study, are aged ≥ 18 years with life expectancy ≥ 1 year, and provide written informed consent, will be included. Eligible patients will be enrolled between 4- and 72-h after completing a successful PCI. Duration of exposure to and dosing regimens of edoxaban, antiplatelet agents and other concomitant medications of interest will be monitored in line with the clinical practice. Physician- and patient-reported clinical events, adverse drug reactions, patient quality of life (EQ-5D-5L) and health resource utilisation (HRU) parameters will be evaluated at 30 days and 1-year post-PCI. The ENCOURAGE-AF non-interventional study will provide insights into the patterns of edoxaban usage in combination with antiplatelet treatment and other concomitant medications in AF patients with a successful PCI over a 1-year time period during routine clinical practice in Germany. The effectiveness and safety of edoxaban in this patient population, as well as patients' quality of life and HRU will be evaluated.Trial registration: Clinicaltrial.gov NCT04519944, registered on 20 August 2020.


Subject(s)
Atrial Fibrillation , Percutaneous Coronary Intervention , Humans , Anticoagulants/adverse effects , Atrial Fibrillation/drug therapy , Drug Therapy, Combination , Platelet Aggregation Inhibitors/therapeutic use , Prospective Studies , Quality of Life , Treatment Outcome
19.
Hum Vaccin Immunother ; 19(2): 2252239, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37655367

ABSTRACT

Cases of thromboembolic events in 2021 flared up the discussion about the safety of Astra Zeneca's AZD1222 vaccine. We hereby report three cases of pulmonary embolism (PE), one case of extended portal vein thrombosis, and one case of combined portal vein thrombosis and PE within 2 weeks after vaccination with the Astra Zeneca AZD1222 vaccine in a 60-year-old, a 50-year old, a 33-year-old, a 30-year old, and a 40-year-old male in that year. All patients were healthy before. In three patients, we observed thrombocytopenia and to some extent unusually low antibody levels for the Spike Protein (S-protein), while the other two had normal thrombocyte counts. Only one patient had anti-platelet factor 4 (PF4)-antibodies detectable as it has been described in the "heparin-induced thrombocytopenia (HIT)-like" disease of "vaccine-induced prothrombotic immune thrombocytopenia" (VIPIT) and we therefore assume that heterogeneous mechanisms led to PE. Therefore, we advise to collect and report more cases, in order to determine the age-related risks of vaccination balanced against the benefits of immunity to SARS-COV-2 for the AZD1222 vaccine in order to gain knowledge for the next pandemic.


Subject(s)
COVID-19 , Thromboembolism , Thrombosis , Male , Humans , Adult , Middle Aged , ChAdOx1 nCoV-19 , COVID-19 Vaccines/adverse effects , COVID-19/prevention & control , SARS-CoV-2 , Antibodies , Immunologic Factors , Thromboembolism/etiology , Platelet Factor 4
20.
Front Cardiovasc Med ; 10: 1213992, 2023.
Article in English | MEDLINE | ID: mdl-37671137

ABSTRACT

Background: Small-vessel coronary artery disease (CAD) is frequently observed in coronary angiography and linked to a higher risk of lesion failure and restenosis. Currently, treatment of small vessels is not standardized while having drug-eluting stents (DES) or drug-coated balloons (DCBs) as possible strategies. We aimed to conduct a meta-analytic approach to assess the effectiveness of treatment strategies and outcomes for small-vessel CAD. Methods: Comprehensive literature search was conducted using PubMed, Embase, MEDLINE, and Cochrane Library databases to identify studies reporting treatment strategies of small-vessel CAD with a reference diameter of ≤3.0 mm. Target lesion revascularization (TLR), target lesion thrombosis, all-cause death, myocardial infarction (MI), and major adverse cardiac events (MACE) were defined as clinical outcomes. Outcomes from single-arm and randomized studies based on measures by means of their corresponding 95% confidence intervals (CI) were compared using a meta-analytic approach. Statistical significance was assumed if CIs did not overlap. Results: Thirty-seven eligible studies with a total of 31,835 patients with small-vessel CAD were included in the present analysis. Among those, 28,147 patients were treated with DES (24 studies) and 3,299 patients with DCB (18 studies). Common baseline characteristics were equally distributed in the different studies. TLR rate was 4% in both treatment strategies [0.04; 95% CI 0.03-0.05 (DES) vs. 0.03-0.07 (DCB)]. MI occurred in 3% of patients receiving DES and in 2% treated with DCB [0.03 (0.02-0.04) vs. 0.02 (0.01-0.03)]. All-cause mortality was 3% in the DES group [0.03 (0.02-0.05)] compared with 1% in the DCB group [0.01 (0.00-0.03)]. Approximately 9% of patients with DES developed MACE vs. 4% of patients with DCB [0.09 (0.07-0.10) vs. 0.04 (0.02-0.08)]. Meta-regression analysis did not show a significant impact of reference vessel diameter on outcomes. Conclusion: This large meta-analytic approach demonstrates similar clinical and angiographic results between treatment strategies with DES and DCB in small-vessel CAD. Therefore, DES may be waived in small coronary arteries when PCI is performed with DCB.

SELECTION OF CITATIONS
SEARCH DETAIL
...